Fire Protection Systems Design in Kenya - Equipment Procurement & Installation o Fire Suppression System Testing (NFPA 11, 13, 25) o Smoke Control Systems T&C o Cause & Effect Fire Matrix Design & Implementing o Fire CFD Modelling (BS 7974 , BS 9991, BS 9999, ADB, NFPA 101) o Fire Safety Training For Hotel and Hospital Staff o Building Fire Strategy Report (ADB) o FLS Consultant in Kenya: email : info@refabse.com

REFABS The Fire Services Hub
We are RE-liable F-ire A-nd B-uilding
S-ervices Engineers And Top Fire Protection Design Consultants, Equipment Suppliers and Installation Contractors.
​
The County (local Authority) by laws for fire protection require the following (section 214):
​
Fire fighting.
214. In any public building, or building of the warehouse class or domestic building, where any floor is more than 20 ft. above the ground level, the council, may require the provision of such fire fighting equipment as it considers necessary, including one or more of the following-
(a) hydrants, hose, hose reels and fire appliance external connections;
(b) portable fire appliance;
(c) sprinkler, drencher and water spray projector system;
(d) water storage tanks; and
(e) dry risers.
​
If your building has more than two floors, talk to us (+254 796490744) to design and build your fire protection system in compliance with the local government requirements. Keep your building and occupants safe and avoid county government penalties by being compliant. Our fire fighting solutions will enhance the fire protection of your property.
​
Our Fire CFD (Computational modelling and simulation of fire for cost effective design) team provides alternative Performance-based, Engineered solutions to Fire Safety Design, whilst offering both flexibility to Architectural designs and cost-effectiveness to building owners. We also perform egress modeling to capture human interaction with a fire situation, thereby providing optimal egress pathways for evacuation. See sample simulations here.
​
Do you need to extend the travel distances within common corridors of residential or commercial buildings? Do you need an analysis of smoke behaviour within the atrium? You will find the solution here.
​
The Performance based fire safety design solution will be at least equivalent to the Deemed-to-Satisfy.
​
Our FLS (Fire Life Safety) Consultancy focuses on:
​
-
Water based fire suppression (sprinklers/hose reel/hydrant)
-
Special suppression (Gaseous, FM200 for server/Foam/Water spray)
-
Smoke control (Staircase & Lift pressurisation / Atrium smoke extract)
-
Fire Alarm Panel Interfacing and Integration (Cause & Effect Fire Matrix)
-
Fire stopping of services penetration
-
Fire doors integrity
-
Egress ways
-
Emergency exit signages
"As a Design Engineer for Building Services, including fire fighting, often I encounter Architectural designs that require engineered solutions. In a recent case I was faced with the task of complying with the Life Safety Code NFPA 101, which provides for safe egress from the building. I needed to ensure compliance by designing the smoke control system in accordance with NFPA 92 B standard which recommends keeping the Make Up Air velocity under 1 m/s. Unfortunately the Architectural concept could not accommodate this requirement owing to the provided area of the supply louvers. The solution was to approach REFABS to verify, through their Fire CFD experts, an alternative engineered solution. This worked well for us as we were able to agree with the Architect and also comply with NFPA 101. I definitely would recommend REFABS Fire CFD Consultants". Peter Odhiambo, Mechanical Engineer at Piimax Inc.
Our Performance Based Fire Safety Design for smoke control makes reference to the following resources:
-
IFC/IBC - section 909
-
NFPA 92, 101 (chapter 5)
-
BS 9999/1, ADB (Reg 2010)
-
ABCB / NCC / ABC - clause A2.2(4)
-
Smoke Control Association (SCA)
-
SFPE Handbook
Fire Protection Products and Services
We major in three key aspects of Fire Protection:



Fire Protection Design & Fire Computational Fluid Dynamics (CFD)
As a Fire Protection or Mechanical Engineer, right sizing smoke extraction fans is key. We computationally model buildings with a real fire scenario helping you correctly size and locate fans for smoke control. Are you an Architect needing an engineered solution like extending travel distances through our Performance based approach? Talk to us. We produce Fire Safety Strategic Reports aligned with the British Building Regulation 2010 code as guided by AD B (Requirements B1-B5 and Regulation 38), BS 9999/1 and 7974 standards. In addition we will also offer performance based smoke control design aligned with the US NFPA 101 building code as guided by NFPA 92.
Fire Protection And Suppression Equipment Supply And Installation Contractors
We supply, install and repair equipment for Passive and Active Fire Protection and Fire fighting. These include Fire Alarm Panels and Systems, 9kg Fire Extinguishers (@ ksh 3900) to Fire Pumps (Jockey, Diesel, Electric) and fire hydrants. Rolling fire and smoke curtains, smoke extraction and Make Up Air fans, Kitchen Hood Ansul Systems, Foam Deluge, Water Spray Nozzles, CO2, FM200 Data Centre Suppression Systems, Smoke, heat, beam, flame, Sounder base detectors. Car park CO and LPG detectors, Jet fans (axial and centrifugal). We also supply Strobe horns, flashers. Sprinklers, Flow Switches, Tamper Switches, landing valve, OS & Y valves, Alarm Check Valve, Breeching inlet, pillar hydrants, Fire hose reels (@ ksh 19500).
Fire Safety Equipment Inspection Testing & Maintenance (ITM)
We provide ITM for fixed water-based fire protection systems complying with NFPA 20 & 25 (Fire pumps churn and flow test), NFPA 24 & 25 (Hydrants), NFPA 13 & 25 (Sprinklers) and NFPA 11 (Foam Deluge). Our Fire Risk Engineers will give vital feedback so your systems can comply with the statutory framework.

We are known to serve both local and International players. These are some of the services our partners have enjoyed:
-
Dormans Coffee (International Coffee Brand situated at Tatu City, Kenya) - as fire suppression systems contractors, we installed their Fire Hydrants System.
-
Hyatt Regency (International Hospitality Brand) - as fire suppression systems contractors and consultants, we designed and installed their fire sprinkler zone control valve units (non-return valve, butterfly valve flow and tamper switches). In addition we are the commissioning Engineers for their Fire Life Safety Systems including Integration of Fire Alarm Panel (See T&C Video).
-
IBERAFRICA (International Thermal Energy Suppliers) - as fire safety and alarm systems contractors, we installed their repaired rotameter and multistage Jockey pump. We also installed their new impeller for the centrifugal electric fire pump. We also conduct annual churn test for them.​
-
Trade Development Bank (TDB - International Banking Brand) - as Fire safety and protection consultants, we performed computational modeling of fire and smoke travel. With the results obtained, we designed and sized their Atrium Smoke extraction system for safe evacuation within tenable conditions.
Our Fire Life Safety Engineering services for design, procurement and installation and Testing & Commissioning (T&C), cover these and more:
​
-
Fire / Smoke detection systems
-
​
-
Water based fire suppression (sprinklers/hose reel/hydrant)
-
​
-
Special suppression (Gaseous, FM200 for server/Foam/Water spray)
-
Smoke control (Staircase & Lift pressurisation / Atrium smoke extract)
-
Fire Alarm Panel Interfacing and Integration (Cause & Effect Fire Matrix Expert) - we specialise in Honeywell (Notifier) and Edwards systems
-
Fire stopping of services penetration
-
Means of Egress